{"id":2148,"date":"2020-05-10T18:26:42","date_gmt":"2020-05-10T18:26:42","guid":{"rendered":"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/?page_id=2148"},"modified":"2020-05-10T18:27:36","modified_gmt":"2020-05-10T18:27:36","slug":"power-distribution-system-description","status":"publish","type":"page","link":"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/male-students\/mg5\/design-approach-implementation-mg5\/power-distribution-system-description\/","title":{"rendered":"Power Distribution System Description (MG5)"},"content":{"rendered":"<p>The QU 39-bus radial distribution system is in Figure \u200e1<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2151 aligncenter\" src=\"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/files\/2020\/05\/p1-12-200x300.jpg\" alt=\"\" width=\"465\" height=\"698\" srcset=\"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/files\/2020\/05\/p1-12-200x300.jpg 200w, http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/files\/2020\/05\/p1-12.jpg 436w\" sizes=\"auto, (max-width: 465px) 100vw, 465px\" \/><\/p>\n<p align=\"justify\">According to KAHARAMA standards, the voltage level in all the QU 39 buses is 11 kV and the maximum voltage fluctuation at all buses should not exceed \uf0b16%. The network is fed from the utility with 67 MVA through a main HV\/MV power station. The main power station contains four transformers rated at 40 MVA each. The current carrying capacity in all cables in the system equals 326 A, since only one type of cables is used, which is the 11KV cable. For each bus, the real power and reactive power are specified as shown in Table \u200e1 based on the data provided by QU-FGSD.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2153 aligncenter\" src=\"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/files\/2020\/05\/p1-13-300x214.jpg\" alt=\"\" width=\"728\" height=\"519\" srcset=\"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/files\/2020\/05\/p1-13-300x214.jpg 300w, http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/files\/2020\/05\/p1-13.jpg 620w\" sizes=\"auto, (max-width: 728px) 100vw, 728px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The QU 39-bus radial distribution system is in Figure \u200e1 According to KAHARAMA standards, the voltage level in all the QU 39 buses is 11 kV and the maximum voltage fluctuation at all buses should not exceed \uf0b16%. The network is fed from the utility with 67 MVA through a main HV\/MV power station. The &hellip; <a href=\"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/male-students\/mg5\/design-approach-implementation-mg5\/power-distribution-system-description\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":465,"featured_media":0,"parent":2138,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-2148","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/wp-json\/wp\/v2\/pages\/2148","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/wp-json\/wp\/v2\/users\/465"}],"replies":[{"embeddable":true,"href":"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/wp-json\/wp\/v2\/comments?post=2148"}],"version-history":[{"count":2,"href":"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/wp-json\/wp\/v2\/pages\/2148\/revisions"}],"predecessor-version":[{"id":2156,"href":"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/wp-json\/wp\/v2\/pages\/2148\/revisions\/2156"}],"up":[{"embeddable":true,"href":"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/wp-json\/wp\/v2\/pages\/2138"}],"wp:attachment":[{"href":"http:\/\/blogs.qu.edu.qa\/ee-sdp-sp2020\/wp-json\/wp\/v2\/media?parent=2148"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}